Sign permit documents – what sign permit documents are required for approval?

Our Services

Cities We Service

Cities We Install Signs In

Get Signage for Your Business

Table of Contents

There’s a standard set of documents you must submit for sign permit approval: a completed application and fee, site plan and scaled elevations showing sign size and location, construction and structural calculations, electrical diagrams and lighting specs, material samples or descriptions, proof of property ownership or owner authorization, contractor licenses and insurance, zoning compliance statements, and photos or maps of existing conditions. Your local authority may require additional forms.

Key Takeaways:

  • Application and site plan: completed permit application, required fees, and a site plan showing the sign location, property lines, setbacks, building elevation, and orientation.
  • Scaled drawings and specifications: detailed elevations and dimensioned drawings, materials and finishes, mounting/attachment details, colors, and illumination specifications.
  • Structural and electrical documentation: engineer-stamped structural calculations for large, roof or projecting signs, plus electrical diagrams and certification for illuminated or powered signs.
  • Ownership, contractor, and insurance: property owner authorization (if tenant), contractor/installer information, proof of insurance and required licenses or bonds.
  • Compliance evidence and special approvals: photos of existing conditions, zoning/code compliance statements, historic district or variance approvals if applicable, and ADA or safety compliance documentation.

Understanding Sign Permits

You’ll encounter permit requirements for freestanding, wall, roof, projecting and awning signs; many municipalities require permits for any sign larger than 2 sq ft or for illuminated signs and those over 6 ft tall. You typically must submit scaled elevations, site plan, material specs, mounting details and electrical permits; review times commonly run 7-30 business days and fees range widely from about $25 to $500 depending on size and complexity.

Definition of Sign Permits

A sign permit is municipal authorization allowing you to install, alter or replace a sign after verification against zoning, building and electrical codes. You submit drawings showing dimensions, placement, materials and lighting; some jurisdictions also demand structural calculations for signs over 50 sq ft or engineered anchors for rooftop or pole signs. In practice this means your application must tie directly to code sections and mounting details so reviewers can confirm compliance quickly.

Importance of Sign Permits

You avoid fines, forced removal and insurance denials by getting permits; typical penalties for unpermitted signs range from $100 to $1,000 per violation and removal costs can exceed $500. You also protect public safety-electrified and tall signs require electrical inspections and wind-load verification-and preserve property value by ensuring signs meet historic district or streetscape standards that many cities enforce through design review.

For example, a retailer who installed an illuminated rooftop sign without a permit faced a $2,500 citation plus $1,200 removal and rework costs; in contrast, a permitted project completed with stamped engineering and an electrical inspection avoided delays and passed final inspection in 14 days. You should factor permit lead times-commonly 2-6 weeks for complex signs-and potential design-review meetings into project schedules to prevent costly last-minute changes.

Types of Sign Permit Documents

You will submit a set that typically includes application forms, a scaled site plan, structural drawings, electrical diagrams and proof of ownership; for local procedures consult Sign and awning permits. Municipal reviewers expect clear dimensions, materials and mounting details up front. This speeds approval and limits review cycles.

  • Application forms and fees
  • Scaled site plan with setbacks
  • Structural drawings and calculations
  • Electrical schematics and load info
  • Proof of ownership or authorization
Document What to include
Application Completed form, contact info, sign type, fees
Site Plan Scale, property lines, sign location, setbacks
Structural Drawings Materials, connections, engineer calculations
Electrical Wiring diagram, voltage, load calculations

Application Forms

You complete the municipality’s permit application and declare sign type (wall, freestanding, awning, projecting), provide owner and installer contact, submit fee receipt, and note whether the sign is temporary; missing contractor license numbers or incorrect dimensions commonly trigger returns.

Site Plans

Your site plan must be scaled (for example 1″=20′ or 1:200), show building elevations, property lines, north arrow, exact sign location with distances to curb, right-of-way and property lines so reviewers can verify compliance with setback and sight-line rules.

Include elevations with sign height above grade, nearby utilities, sidewalk width and parking stalls; for freestanding signs show distance to ROW and a common example is a 5 ft minimum clearance from pedestrian walkways in many local codes, which helps avoid field corrections.

Structural Drawings

Your structural drawings should show plan and elevation views, member sizes, weld and anchor details, material specs and design calculations; a licensed engineer’s stamp is often required for signs over a certain height or wind-exposed locations to demonstrate safety under expected loads.

Supply load calculations referencing local code wind and seismic criteria, specify anchor type and embedment depth, note corrosion protection and provide a signed title block; reviewers frequently reject sheets without a PE stamp or without clear connection details such as bolt sizes and plate thicknesses.

Supporting Documentation

Permits from Other Authorities

You may need approvals beyond the local sign office: state DOT for signs within 50 ft of a highway, FAA for structures over 60 ft, fire department for illuminated or electronic signs, and historical commissions for listed buildings. Fees typically range $50-$1,000 and review times from 2-12 weeks; plan submissions should include drawings and coordination letters from each authority to avoid sequential delays.

Owner Consent Forms

If you lease a storefront, obtain written owner consent identifying the property owner, parcel or tax ID, and authorization scope; many municipalities require a signed, dated, and often notarized form. Include contact info for the owner or property manager and attach the lease or deed; lacking clear consent commonly triggers permit denial or a hold for several weeks.

Draft the consent to reference the permit application number, list specific sign dimensions and placement, and state how long the authorization remains valid; you should get signatures from all title holders or a board resolution if an HOA owns the property. Electronic signatures and scanned documents are accepted by many agencies, but keep originals and proof of authority (power of attorney, corporate resolution) in case the inspector requests them.

Local Regulations and Compliance

Municipal and state rules shape what you can build: zoning maps, historic-district design standards and state DOT setbacks all apply. Expect height caps (often 20-35 ft), area limits (commonly 50-300 sq ft), and setback rules (5-50 ft depending on frontage). You must verify local code, provide engineered drawings when required, and factor other approvals-failure to comply can mean fines, removal orders or rework that delays opening.

Zoning Requirements

Zoning districts define permitted sign types and sizing: C-1 or C-2 commercial zones typically allow larger wall and freestanding signs, while residential zones restrict or prohibit them. Many jurisdictions size signs by linear frontage (for example, 1 sq ft per linear foot capped at 200 sq ft). Corner clearances of 25-50 ft and minimum setbacks from property lines are common; check your parcel’s zoning designation and permitted variances before finalizing designs.

Signage Guidelines

Material, mounting, illumination and safety standards govern approval. You’ll often need stamped structural calculations (especially for signs over 100 sq ft or in wind zones ≥90 mph), UL-listed electrical components, and limits on brightness or flashing-municipal thresholds commonly cap illumination or ban animated signs. Historic districts may require traditional materials like wood and painted finishes instead of exposed LEDs or vinyl.

Further, many jurisdictions require a photometric plan showing footcandles at property lines, timers or dimmers to meet night-time limits (examples: max 300 cd/m² or locally specified lux), and maintenance/inspection schedules every 3-5 years. You should submit manufacturer specs, UL listings, conduit routing diagrams and a removal/bond plan if temporary or for tenant signage; these details speed approval and reduce revision requests.

Application Process

When you prepare your application, assemble required documents-typically three printed plan sets plus one digital copy, a site plan showing setbacks, elevation drawings, structural calculations for large or tall signs, and owner authorization; many jurisdictions charge $50-$300 in filing fees and offer online portals where you can upload PDFs and track status within 24 hours.

Submission Steps

First, complete the municipality’s application form and attach scaled drawings, material specs, electrical details for illuminated signs, and structural stamps where applicable (many places require calculations for signs over 200 sq ft or taller than 15 ft). Then pay the fee, submit via the local portal or counter, and provide utility locates or easements if the sign is near right‑of‑way; you’ll get a checklist or intake receipt confirming completeness.

Review Timeline

Expect an initial completeness check within 2-5 business days and a substantive review of 10-30 business days; if plan corrections are requested, each resubmission commonly adds 7-14 business days, while expedited review options (when available) can reduce turnaround to 48-72 hours for an added fee.

In practice, timelines vary: for example, a 50‑sq‑ft illuminated tenant sign in a mid‑sized city often sees a 14‑day architectural review plus a 7-10 day structural review, resulting in roughly 3-4 weeks before approval; after approval, schedule the final inspection-most jurisdictions provide inspection slots within 3-7 business days of booking, or same‑week inspections when contractors report emergency or code compliance issues.

Common Challenges and Solutions

Incomplete plans, missing structural calculations, and zoning conflicts are frequent stumbling blocks; you should expect municipal reviewers to request three printed plan sets plus a digital copy and to take 10-30 business days for first review. Many jurisdictions require stamped structural calculations for signs over ~100 sq ft or taller than 12 ft, so hire a licensed sign contractor and structural engineer up front. Scheduling a pre-submittal meeting often reduces resubmission cycles from three to one or two and clears specific code interpretations.

Denied Applications

Denials usually cite nonconforming sign area, setback violations, missing easement or landlord approval, or inadequate lighting/illumination details; when your application is denied, review the denial letter for the exact code citations and corrective items. Most agencies give 30 days to correct and resubmit, so promptly supply revised plans, stamped calcs, or a site-use agreement to avoid starting a new application process.

Appeals Process

If you dispute a denial, file an appeal within the jurisdictional deadline-commonly 14-30 days-and expect a hearing before a zoning board or sign appeal committee. Appeal fees commonly range $100-$500; bring concise evidence (revised plans, photos, engineering reports) and a representative such as your engineer or sign vendor to present technical remedies that address the denial points.

Prepare a focused appeal packet: cover letter, three printed plan sets plus one digital copy, stamped structural calculations, photometric or lighting plans, and any neighbor or landlord approvals; submit 10 copies to the clerk where required. Hearing waits typically run 2-8 weeks; at the hearing you can request a variance, conditional approval, or negotiated mitigation (for example, reducing sign area from 150 to 100 sq ft and adding engineered anchorage), which has turned denials into approvals for many retail and multi-tenant cases.

Summing up

Now you need to submit a complete application package to gain approval: the signed application form, site plan and scaled sign drawings showing dimensions and materials, lighting and electrical details, structural calculations or engineer’s stamp for large or mounted signs, proof of property ownership or owner consent, photos of the existing site, contractor licenses, zoning compliance documentation, and payment of applicable fees and permits.

FAQ

Q: What documents are generally required to file a sign permit application?

A: A complete submittal typically includes a signed and completed application form, payment of fees, a scaled site plan showing sign location and distances to property lines and rights-of-way, scaled elevation drawings showing sign dimensions and materials, overall square footage and height calculations, a vicinity map, color renderings or photos of the proposed sign, photos of the existing site/building, contractor or installer license information, proof of ownership or owner authorization, and any required structural calculations or engineer’s stamp for larger or freestanding signs.

Q: When are structural or engineer-stamped drawings required?

A: Engineer-stamped structural drawings are usually required for freestanding signs, pole signs, or any sign with a support structure that exceeds local height, area, or wind-load thresholds. Typical triggers include signs over a specified height (often 6-8 feet above grade), signs over a specified face area (commonly 50 sq ft or more), and signs with multiple attachments or heavy materials. The submission should show foundation details, connection details, wind-load calculations, material specifications, and an engineer’s certification where local code demands it.

Q: What electrical documentation is needed for illuminated or electronic signs?

A: Illuminated sign submittals usually require an electrical permit application, wiring diagrams showing conductor sizes and routing, power supply and transformer specifications, load calculations, a description of lighting type (LED, neon, etc.), UL listing or manufacturer product sheets, location of disconnect and service point, licensed electrician information, and any photo control or dimming control details. Some jurisdictions also request photometric data for electronic message centers and proof of compliance with local brightness/hour restrictions.

Q: What proof of ownership or authorization must be included if I’m not the property owner?

A: If the applicant is not the property owner, provide a property deed or recent tax bill to prove ownership, and a notarized letter of authorization or signed lease showing the owner’s consent for the sign work. For tenant-mounted signs, include the tenant’s lease page granting signage rights or a landlord-signed authorization form. If the sign is on public right-of-way or easement, include recorded easements or permits from the relevant public agency.

Q: How do I demonstrate compliance with zoning, setbacks, and design standards in my application?

A: Include a site plan with dimensions to property lines, curb, and nearest structures; label building frontage and sign setbacks; provide elevation drawings showing clearance to sidewalks and overhangs; list sign area and height calculations with the zoning code references used; attach photos of existing site conditions and adjacent signage; submit any required variance, conditional use, or design review approvals if the proposal deviates from standards; and provide a short compliance statement citing applicable code sections and how the design meets each requirement.

Scroll to Top